SMART disks
This section describes the alerts for SMART disks.
SystemSMARTDiskUDMACrcErrorsTooHigh
Severity |
Warning |
Summary |
The {{ $labels.device }} disk has UDMA CRC errors. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node is
reporting SMART UDMA CRC errors for 5 minutes. |
SystemSMARTDiskHealthStatus
Severity |
Warning |
Summary |
The {{ $labels.device }} disk has bad health. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node is
reporting a bad health status for 1 minute. |
SystemSMARTDiskReadErrorRate
Severity |
Warning |
Summary |
The {{ $labels.device }} disk has read errors. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node is
reporting an increased read error rate for 5 minutes. |
SystemSMARTDiskSeekErrorRate
Severity |
Warning |
Summary |
The {{ $labels.device }} disk has seek errors. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node is
reporting an increased seek error rate for 5 minutes. |
SystemSMARTDiskTemperatureHigh
Severity |
Warning |
Summary |
The {{ $labels.device }} disk temperature is high. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node has
a temperature of {{ $value }}C for 5 minutes. |
SystemSMARTDiskReallocatedSectorsCount
Severity |
Major |
Summary |
The {{ $labels.device }} disk has reallocated sectors. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node has
reallocated {{ $value }} sectors. |
SystemSMARTDiskCurrentPendingSectors
Severity |
Major |
Summary |
The {{ $labels.device }} disk has current pending sectors. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node has
{{ $value }} current pending sectors. |
SystemSMARTDiskReportedUncorrectableErrors
Severity |
Major |
Summary |
The {{ $labels.device }} disk has reported uncorrectable errors. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node has
{{ $value }} reported uncorrectable errors. |
SystemSMARTDiskOfflineUncorrectableSectors
Severity |
Major |
Summary |
The {{ $labels.device }} disk has offline uncorrectable sectors |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node has
{{ $value }} offline uncorrectable sectors. |
SystemSMARTDiskEndToEndError
Severity |
Major |
Summary |
The {{ $labels.device }} disk has end-to-end errors. |
Description |
The {{ $labels.device }} disk on the {{ $labels.host }} node has
{{ $value }} end-to-end errors. |